Installation Instructions for #81556A
Replacement Cutter/Nozzle for Powered Nibbler
Please read through and understand these instructions before attempting disassembly of your Powered Nibbler.

To replace the cutter/nozzle assembly, complete the following steps:
  • Disconnect the line cord from the wall socket.

  • Remove two screws #35 using the large hex key.

  • Remove set screw #31 using the small hex key.

  • Remove head cap #2 by pulling straight up.

  • Remove two screws #34 using the hex key that came with your Powered Nibbler.

  • Remove retainer #15 from drive assembly.

  • Remove cutter bar #14 by gently tapping it down and out.

  • Remove the nozzle assembly #16/17/18/19.

  • If replacement parts #13, 15, and 34 are attached to the new cutter bar/nozzle assembly, remove them.

  • Replace parts #12 and #13 if necessary. Otherwise, save for future use.

  • Install new cutter bar #14 and retainer #15. Be careful to make sure that the short groove in #14 properly mates with parts #13 and #15. Secure by reinstalling screws #34.

  • Install new nozzle assembly. Be sure recess on side of assembly aligns with set screw hole.
  • Reinstall and tighten set screw #31.

  • Apply grease to all moving parts. Shield mechanism to prevent grease from splattering in the next step.

  • Plug in tool and run momentarily to be sure everything works as it should. If any binding occurs, determine the cause and readjust everything so the tool runs smoothly.

  • Reattach head cap and secure with two screws #35.
Nibbler Line Art


Go to #81556A Catalog Page